The i-Vision control unit contains the latest environmentally friendly technology. It has a unique power saving function and provides an extraordinary range of functions.
All models in the new iV-5 series offer the following benefits as standard. Additional features are listed with the respective model.
For telescopic lip levellers
Standard control unit for all ‘Performance’ hydraulic dock levellers with a telescopic lip
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 2,4A/ 4,2A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
TM24020001150
Control unit for ‘Performance’ hydraulic dock levellers with a telescopic lip and doors, for DCC80 operator
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 2,4A/ 4,2A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
TM24050001150
Control unit for ‘Performance’ hydraulic dock levellers with a telescopic lip and doors, for DCC80 operator + inflatable door seal
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 2,4A/ 4,2A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
TM24057001150
Control unit for ‘Performance’ hydraulic dock levellers with a telescopic lip and doors, incl. door control unit for GFA operator, double housing and inflatable door seal
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 2,4A/ 4,2A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
TM24059001150
Replacement control unit for hydraulic dock levellers with a telescopic lip
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 2,4A/ 4,2A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
TM24080001150
All models in the new iV-3 series offer the following benefits as standard. Additional features are listed with the respective model.
For telescopic lip levellers
Control unit for all ‘Performance’ hydraulic dock levellers with a hinge lip
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 2,4A/ 4,2A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
TM24010001150
Control unit for ‘Performance’ hydraulic dock levellers with a hinge lip and doors, for DCC80 operator
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 2,4A/ 4,2A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
TM24040001150
Control unit for ‘Performance’ hydraulic dock levellers with a hinge lip and doors, for DCC80 operator + inflatable door seal
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 2,4A/ 4,2A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
TM24046001150
Control unit for ‘Performance’ hydraulic dock levellers with a hinge lip and doors, incl. door control unit for GFA operator double housing and inflatable dock shelter
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 2,4A/ 4,2A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
TM24049001150
Replacement control unit for hydraulic dock levellers with a hinge lip
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 2,4A/ 4,2A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
TM24070001150
With the new i-Vision control units you always have optional access to the status of all installed door and loading systems. Wherever and whenever it is important to you.
Monitoring and control in real time
Digital support for service staff, maintenance managers and warehouse management brings maximum transparency to our loading area. This means you have everything under control in just one spot at all times and can act proactively.
Connection via the app
The smart assistant for step-by-step commissioning, service and maintenance of door and loading systems simplifies the installation and and adjustment of the doors, operators and control units with the following functions:
NovoServiceHub
Throughout the innovative live monitoring solution, all service and maintenance services can be monitored and managed centrally. Benefit from the following advantages:
For telescopic lip levellers
Standard control unit for telescopic lip levellers with a two-valve hydraulic system
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 4.2 A; 2.4 A/7.5 A; 4.2 A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
Telescopic lip levellers with a two-valve hydraulic system and door control
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 4.2 A; 2.4 A/7.5 A; 4.2 A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
Telescopic lip levellers with a two-valve hydraulic system and door control for doors from other manufacturers
(Door control must be available)
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 4.2 A; 2.4 A/7.5 A; 4.2 A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
Telescopic lip levellers with a two-valve hydraulic system, door control and inflatable dock shelter control
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 4.2 A; 2.4 A/7.5 A; 4.2 A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
Pure replacement solution for telescopic lip levellers with a two- or three-valve hydraulic system and door control for doors from other manufacturers
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 4.2 A; 2.4 A/7.5 A; 4.2 A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
A separate door control is needed for doors from other manufacturers.
Pure replacement solution for telescopic lip levellers with a two- or three-valve hydraulic system
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 4.2 A; 2.4 A/7.5 A; 4.2 A
Connection: CEE plug as standard
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
For hinge lip levellers
Standard control unit for hinge lip levellers with a single-valve hydraulic system
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 4.2 A; 2.4 A/7.5 A; 4.2 A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
Hinge lip levellers with a single-valve hydraulic system and door control
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 4.2 A; 2.4 A/7.5 A; 4.2 A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
Hinge lip levellers with a single-valve hydraulic system and door control for doors from other manufacturers
(Door control must be available)
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 4.2 A; 2.4 A/7.5 A; 4.2 A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
Hinge lip levellers with a single-valve hydraulic system, door control and an inflatable dock shelter
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 4.2 A; 2.4 A/7.5 A; 4.2 A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
Pure replacement solution for hinge lip levellers with a two-valve hydraulic system and door control for doors from other manufacturers
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: 0.75 kW/1.5 kW
Rated current: 4.2 A; 2.4 A/7.5 A; 4.2 A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
A separate door control is needed for doors from other manufacturers.
Other components that are included in all our Novo i-Vision control units as standard:
Function:
Locking the door/dock leveller
Thread type M12 x 1, incl. 6 m cable, OF 5070
DS0220001
Function:
Scanning in rest position Suitable for: L530i
Incl. 10 m cable, Osiprox XS8E
DS0220100
Use:
Installation in roof tarpaulin of the dock shelter
Incl. 5 m cable and bracket
DS0220160
Only door control
Supply voltage: 230/400 V/AC (+10 %, -15 %) 50/60 Hz, 3/N/PE
Motor power: max 3 kW
Rated current: 4.2 A; 2.4 A/7.5 A; 4.2 A
Connection: CEE plug as standard
Control voltage: 24 V/DC, max. 2 A
IP code: IP65
Housing colour: graphite grey RAL7024
Operating temperature: -20 °C to +50 °C
DS0231280
Function:
Locking the control unit, resetting the maintenance display
DS0290010
hinged lip levellers with 1 MV
230/400V, without connector assembly, without auto-button
DS0240000
Older models
DS0291010
Version 1
Version 2
Version 1
DS0291000
Version 2
DS0291000
DS0291030
DS0291020
docking Solution und
Service GmbH
Springrad 4
30419 Hannover
Tel. +49 (0)511 76 36 79-0
Fax +49 (0)511 76 36 79-90
info@mydocking.com
www.mydocking.com
© 2024 | docking Solution und Service GmbH